Add to Cart
100A 6300A 380V 660V 50Hz ACB Air Circuit Breaker MCCB Performance Heat Resistant
Application
ZMW50-1000 conventional circuit breaker (hereinafter call “breaker”) is suitably used in the distribution circuit of AC 50Hz, rated voltage 400V, rated current 200 ~1000A, to distribute electric power and protect circuit and equipment from overloading, short circuit, under-voltage, single phase earthing, residual current faults. At normal working conditions the breaker can be used to transfer the distribution lines or start the motor non-frequently. The breaker provides the intelligent protection function and high precise selective protection, improve the reliability of power supply, and prevent unnecessarily cutting off power supply. The breaker has isolation function.
Normal Working Condition
Temperature: -5℃-+40℃, the average can't more than+35℃ with in 24 hours.
Altitude: not higher than 2000m for the installation site.
When the ambient air temperature is +40℃, the relative humidity of the air shall not be higher than 50%; a higher relative humidity is allowed at a lower temperature; special measures shall be taken for the condensation occasionally produced due to temperature change.
Degree of Pollution: III
Use Category: B type
Installation conditions: the mounting inclined angel shall not more the +5°
Model
Main Techincal Data
1.Circuit breakers rated insulation voltage 690V; rated working voltage of 400V, 690V
2.Rated short circuit making capacity of breaker shall not be less than 2.1Icu.
3.Circuit breakers rated current
Frame size rated current | Rated Current | Rated controller current |
1000 | 200, 400, 630, 800, 1000 | 200, 400, 630, 800, 1000 |
4.Rated short circuit breaking capacity and short time withstand current
Frame size rated current | Rated limited short-circuit breaking capacity (kA)COS∅ | Rated short-circuit breaking capacity | Rated short time withstand current (kA)COS∅ | Arcing distance | Connection | |
(kA)COS∅ | ||||||
380(400)V | 380(400)V | 380(400)V | 380(400)V | |||
Short time 1s Delay 0.25s | Short time 0.5s Delay 0.25s | |||||
1000 | 42 | 30 | 20 | 30 | no arc | Up or down |
External And Installation Size
1.Faxied type
2.Draw-out type
Circuit breakers perform 3 key functions: protection, switching, and monitoring. Circuit breakers are designed to “break” (discontinue) the flow of electricity to protect people and equipment when current reaches an unsafe level due to overload, short circuit, or other electrical faults. We are your one source solution for all your circuit breaker and equipment needs.
Normally, we will provide the most suitable shipment method for you. If the quantity is few, the goods will be sent by express when the payment is clear. Also, we can transport the goods by air or by sea, just according to your demand
Sichuan Baikong Electrical Technology Co.,Ltd has perfect testing equipment and strict testing standards, perfect management and operation and quality assurance system. The company adheres to the enterprise purpose of synchronizing with the world and win-win with customers, adhering to scientific management, loyal to design, pioneering and innovation, and tree corporate image Business philosophy, and fully understand customer needs, do the customers think, with customers to create, win-win best control electrical staff continuously forge ahead The spirit of pragmatic innovation, serving the power construction at home and abroad to compose the new chapter The control electrical products successively in the national key projects and large enterprises are widely used, and to get the customer the consistent approval .
Sichuan Baikong Electric Technology Co., Ltd sincerely look forward to the presence and cooperation of old and new customers and win-win new future together.