Bypass regulator UPS bypass cabinet 60KW/100KW regulator
Overview
ES-ZW series non-contact voltage stabilizer is a new generation of non-contact AC stabilized power supply developed and produced in response to the high requirements of high-precision equipment on the market for power grids; it has a fast response speed and voltage stabilization accuracy. High, no contact, no wear, no interference, complete protection functions, fully automatic, maintenance-free, three-phase voltage adjustment and automatic balance; using large-scale integrated circuit control core, fully automatic operation, complete protection functions, no
personnel on duty.
This series of regulators retains all the advantages of mechanical compensation, parametric and magnetic compensation regulators, and specifically avoids the shortcomings of mechanical compensation, such as slow dynamic response, easy wear of carbon brushes, and ignition, and overcomes the parameters The inherent shortcomings of the voltage stabilizer are poor load adaptability, low efficiency of the magnetic compensation type voltage stabilizer, and large harmonic content.
Since its listing, it has been widely used in processing and manufacturing, rail transit, medical equipment, communications industry, equipment testing and other fields, and has won unanimous praise from users.
Technical parameters of 120KVA non-contact voltage regulator
Serial number | category | specification | |
1 | Product number | ES-ZW-S120R15 | |
2 | Rated Capacity | 120KVA | |
Input voltage | Three-phase 3L+N+G 323~437V | ||
3 | enter | frequency | 50/60Hz |
Rated working current | 145.8A | ||
Rated output voltage | Three-phase 3L+N+G 380V | ||
Output voltage accuracy | ±1% | ||
Response time | ≤40ms | ||
4 | Output | Waveform distortion | No additional waveform distortion (static) |
Work efficiency | ≥98% | ||
Voltage stabilization method | Three-phase independent adjustment, automatic balance | ||
Load characteristics | Resistive, capacitive, inductive, mixed load, support 100% unbalanced load | ||
Protective function | Overpressure | The output voltage is higher than 10% (phase voltage L-N242V), cut off the output or uninterrupted to bypass (standard configuration to bypass) | |
Undervoltage | The output voltage is lower than 10% (phase voltage L-N198V), cut off the output or uninterrupted to bypass (standard configuration to bypass) | ||
overload | Electronic detection and circuit breaker dual protection, 150% overload, cut off the output in 1 minute or uninterrupted to bypass (standard configuration to bypass) | ||
Short circuit | Electronic detection and circuit breaker double protection | ||
5 | bypass | Uninterrupted automatic bypass or manual bypass (standard automatic bypass) | |
Delayed output | Stabilize first and then output (protect the electrical equipment from impact), you can choose automatic delayed output or manual output (optional) | ||
Display content | Input and output voltage | True RMS 4-digit LCD liquid crystal display, resolution 0.1V | |
Input Current | True effective value 4-digit LCD liquid crystal display, resolution 0.1A | ||
6 | Operating mode | Continuous operation, with two working modes: regulated output and mains output | |
record | Overvoltage, undervoltage, overload, fault code prompt | ||
Insulation class | Class F/Class H | ||
7 | 其他 | Insulation resistance | >5MΩ |
Dielectric strength | 2500VAC/1min no flashover, no breakdown |